How does guided wave radar level transmitter work and how to configuration and calibration full details.


 

GWR Level Transmitter Basics


Guided wave radar (GWR) level transmitters are commonly used in industries to measure the level of liquids and solids in tanks, vessels, and silos. GWR level transmitters use a guided wave probe that is inserted into the tank or vessel, and the probe sends a radar signal down the length of the probe. The signal then reflects off the liquid or solid material and returns to the probe, allowing the transmitter to calculate the level of the material in the tank or vessel.


Working Principle:


GWR level transmitters work based on time-domain reflectometry (TDR) technology. The guided wave probe is typically made of a metal rod or cable, and the probe is inserted into the tank or vessel to a specific length. The probe acts as a waveguide for the radar signal, which is sent down the length of the probe. When the radar signal reaches the end of the probe, it reflects back to the transmitter. The transmitter measures the time it takes for the signal to travel down the probe and back, which is used to calculate the level of the liquid or solid material in the tank or vessel.


Configuration:


To configure a GWR level transmitter, you need to follow the manufacturer's instructions carefully. The configuration process typically involves connecting the transmitter to a computer or handheld device and entering the necessary parameters, such as the tank height, probe length, and dielectric constant of the material being measured. The dielectric constant is a measure of the material's ability to store electrical energy, and it is important for calculating the level of the material accurately.


Calibration:


Calibrating a GWR level transmitter involves setting the zero and span points. The zero point is the level at which the transmitter indicates zero, and the span point is the level at which the transmitter indicates 100%. To calibrate the transmitter, you need to fill the tank or vessel with the material being measured and adjust the zero and span points until the transmitter accurately indicates the level of the material.


Here are the steps to calibrate a GWR level transmitter:


1. Verify that the transmitter is connected to the tank or vessel and that the guided wave probe is properly inserted.

2. Fill the tank or vessel with the material being measured until it reaches the desired level.

3. Adjust the zero point of the transmitter until it indicates zero when the material level is at the bottom of the tank or vessel.

4. Adjust the span point of the transmitter until it indicates 100% when the material level is at the top of the tank or vessel.

5. Repeat steps 3 and 4 until the transmitter accurately indicates the level of the material at different levels in the tank or vessel.

6. Verify that the transmitter is working properly by checking the readings against the actual level of the material in the tank or vessel.

In summary, GWR level transmitters work by sending a radar signal down a guided wave probe, which reflects off the liquid or solid material and returns to the transmitter. To configure and calibrate a GWR level transmitter, you need to follow the manufacturer's instructions carefully and set the necessary parameters, such as the tank height, probe length, and dielectric constant of the material being measured. Calibration involves setting the zero and span points of the transmitter to accurately indicate the level of the material in the tank or vessel